Tools
Gas Specs
Analyse any nitrox or trimix mix at any depth: PPO₂, equivalent air depth (EAD), equivalent narcotic depth (END), gas density, and maximum operating depth (MOD).
Last updated October 30, 2026
Free web calculator: Nitrox MOD and EAD Calculator →
On this page
What it is
Gas Specs takes a breathing mix and a depth, then tells you everything that matters about how that gas behaves there. Where Best Mix designs a blend for you, Gas Specs analyses one you already have. Set the oxygen and (for trimix) helium fractions, set the depth, and read the numbers.
The in-app title is “Gas Specs” (the same name appears on the home card and in the header). Internally the tool is the gas analyzer at the plan/ead-ppo2 route, so older references to “EAD/PPO₂” or “Gas Analyzer” point at this same screen.
How to use it
Set the oxygen
Add helium if it's trimix
Set the depth
Read the results
Tap a figure to learn what it means
O₂ runs 5 to 100%, He 0 to 100%, and depth 1 to 300 m (3 to 984 ft). The tool opens at air (21% O₂, 0% He) at 12 m. The field you are typing into stays above the keyboard.
O₂ and He can’t add up to more than 100%, so raising He lowers O₂ to fit. If that pushes O₂ under 5%, the O₂ field turns red with a line explaining why, every figure shows a dash, the heading reads “No result”, and the warnings wait until you raise O₂ back to 5% or more.
Depth follows your unit setting, in metres or feet. PPO₂ is always reported in bar, never converted. The line above the results names the mix and depth, plus the water type and water temperature from Settings → Diving that the figures use.
What each output means
Each figure shows a short label. The top three carry a status note under the value; the reference depths carry a short subtitle under their label.
| Output | Shown in app | Meaning |
|---|---|---|
| Oxygen partial pressure | PPO₂ (bar value; note “within 1.4”, “deco only”, “over 1.6”, or “under 0.16” for a hypoxic mix in the shallows) | Partial pressure of oxygen: PPO₂ = FO₂ × absolute pressure. The toxicity number. |
| Equivalent air depth (EAD) | EAD | The depth at which plain air gives the same nitrogen loading as your mix. Lets you reuse air-based no-deco thinking on nitrox. Helium is excluded. |
| Equivalent narcotic depth (END) | END (note “N₂ only”, or “N₂ + O₂” when Treat O₂ as narcotic is on) | The air-equivalent depth for narcosis. Tells you how clear-headed the mix keeps you at depth. |
| Maximum operating depth, working | MOD 1.4 | Deepest depth at a 1.4 bar working limit, for active swimming. |
| Maximum operating depth, deco | MOD 1.6 | Deepest depth at a 1.6 bar limit, for resting and deco stops only. |
| Gas density | Gas Density (g/L value; note “easy”, “elevated” or “too dense”) | Real density of the mix at depth. Dense gas is hard to breathe and traps CO₂. |
| Equivalent air density depth (EADD) | EADD | The depth at which air has the same density as your mix, a quick read on breathing effort. |
| No-decompression limit (NDL) | NDL (minutes; “Deco stop required” when it is 0) | Minutes you can stay at this depth on this mix before a decompression stop becomes mandatory, at your default GF high. See No-stop time. |
| Minimum breathable depth | Min Depth (subtitle “hypoxic above it”) | For hypoxic mixes only: the shallowest depth where PPO₂ reaches the 0.16 bar floor and the gas is breathable. Shown beside the MODs, amber when you are at or below it and red when you are shallower. |
The results show both MODs at once: a working MOD at PPO₂ 1.4 (MOD 1.4) and a deco MOD at PPO₂ 1.6 (MOD 1.6), so you can see the active-swim limit and the deco-stop limit side by side without changing a setting. A MOD is rounded down to a whole metre or foot after converting, so it never reads deeper than the true limit (EANx32’s working MOD is 33 m or 110 ft).
No-stop time (NDL)
The NDL stat is the no-decompression limit: how many minutes you can stay at this depth on this mix before a decompression stop becomes mandatory. The Deco Planner’s engine (Bühlmann ZH-L16C) descends from the surface on this mix at your default descent rate, then counts from the moment you arrive. It is the same figure the Deco Planner shows on a level of that depth and gas. It uses your default gradient factors from Manage → Settings → Deco Planner, and its help sheet (tap the NDL figure) names the GF high it used. With the stock GF 50/80 and air, 30 m (100 ft) gives about 10 minutes.
- A dash means the figure is still being worked out, or the engine could not answer.
- ∞ (“No limit”) means the model sets no practical limit at this depth, as in the shallows on air.
- 0 min (“Deco stop required”, amber) means a stop is already mandatory on arrival.
Narcotic-gas assumptions
EAD and END both convert a partial pressure back into the depth on air that would produce it, using the absolute pressure for your water type:
- EAD uses the nitrogen fraction only. It finds the depth at which air’s nitrogen partial pressure matches your mix’s, then reports that depth. Helium is treated as non-narcotic and excluded, since EAD measures nitrogen loading (your decompression reference), not narcosis.
- END depends on whether you count oxygen as narcotic. This is the Treat O₂ as narcotic toggle in Settings → Diving; the END help sheet shows whether it is on and opens that setting. With it off, only nitrogen narcoses, so END equals EAD. With it on, everything except helium narcoses (nitrogen plus oxygen), which raises your END at the same depth. Turning it on is the more conservative reading.
Gas density uses standard surface densities (O₂ 1.429, N₂ 1.251, He 0.1786 g/L) scaled by absolute pressure, then by the water temperature. Those constants are measured at 0 °C (32 °F), so the reading is multiplied by 273.15 / (273.15 + T), where T is the Water temperature you set in Settings → Diving (default 15 °C / 59 °F). Gas gets thinner as it warms, so a warmer setting reads lower. The 5.2 and 6.2 g/L limits below are published figures and do not move with the temperature, which means a warmer setting warns a little deeper. EADD compares the mix against air’s surface density and is a ratio, so the temperature cancels out of it.
Warnings
PPO₂, gas density, NDL at 0 and the minimum depth carry a status: a ✓ when within the limit, an amber tint and ▲ for a caution, a red tint and ■ when over the limit. END, EAD, EADD and both MODs have no status. The pill beside the heading shows the most serious status on screen; when two are equally serious, PPO₂ comes first, then hypoxia, then density. Warning cards below the figures explain each one:
- High PPO₂. Above the 1.4 bar working limit the PPO₂ reads “deco only” and the warning says to avoid it while swimming. Above 1.6 bar it reads “over 1.6” and warns of seizure and blackout risk. Both limits allow the same 0.03 bar tolerance the Deco Planner uses for gas switches, so the caution starts above 1.43 bar and the red above 1.63 bar.
- Gas density. Above 5.2 g/L it cautions and suggests adding helium. Above 6.2 g/L it warns of CO₂ buildup and tells you to add helium or reduce depth. The density is judged as shown, at one decimal, so 5.24 g/L reads 5.2 and does not trip the 5.2 limit. Both limits are user-adjustable defaults (5.2 and 6.2 g/L), set in the deco and gas defaults.
- Hypoxic mix. Any mix that needs more than surface pressure to reach the 0.16 bar floor (roughly under 16% O₂) is hypoxic at every depth, and the tool shows the depth above which it is not breathable. The warning is amber when you are at or below that depth, and red when you are shallower; then PPO₂ also reads “under 0.16” in red.
The O₂ and He fields cannot produce an impossible mix. Raising O₂ past 100 − He percent automatically lowers He (and raising He past 100 − O₂ percent lowers O₂), so the two fractions always sum to 100% or less.
Behaviour and limits
On a tablet held in landscape the screen splits into two columns: the O₂, He and depth inputs on the left; the heading pinned at the top right with the results and warnings scrolling under it. Each column scrolls on its own. On a phone, or on a tablet held upright, the tool stays one scrolling column.
Gas Specs reflects only the numbers you type in. It assumes the mix is exactly what you entered, so analyse and label your real cylinder before diving.
Related
- Best Mix Calculator designs the mix that Gas Specs analyses.
- Deco Planner uses the same PPO₂ and MOD logic to schedule gas switches on a full dive.
Parts of this guide were drafted with AI assistance and may contain mistakes. It's educational, not a substitute for training. Always dive within your certification and verify with your instruments.