Contents

Tools

Deco Planner

Plan multi-level, multi-gas decompression dives on open circuit or CCR with the Bühlmann ZH-L16C engine and configurable gradient factors.

Last updated November 1, 2026

On this page

What it is

The Deco Planner builds a complete decompression schedule for a planned dive: descent, time at each level, ascent, every required stop, and the gas you will breathe along the way. It runs the Bühlmann ZH-L16C algorithm with gradient factors, so its output lines up with established planners like MultiDeco.

It handles both open circuit (OC) and closed circuit rebreather (CCR) dives, multiple gases with automatic switching on ascent, repetitive dives that carry tissue loading forward, contingency scenarios, and sharing a plan with your buddy by link or QR code.

The Deco Planner is a Dive Kit Pro feature. Without Pro you can open a plan a buddy shared and read every output, but you cannot create or edit one. A shared plan opened without Pro shows a Read-Only Plan banner with an Unlock Dive Kit Pro button, and it is not kept when you leave the screen.

The rest of this guide

This page is the tour: how to start a plan, how to describe the dive, and how to get around the screen. Four more pages are the reference.

PageWhat it covers
Gases in the Deco PlannerEvery field in the gas sheet, MOD and the PPO₂ bands, a reserve for one cylinder, automatic gas switching, and what happens when a cylinder runs out
Deco Planner settingsEvery setting row in order, with its range, default, and whether it moves your stops
Reading a deco planThe stats pill, the profile graph, the stop table, the Gas Consumption card, the bottom time finder, and every warning
Contingencies and plan modifiersThe scenario tabs, building your own, and the four plan modifiers

Rebreather divers should also read CCR diving, which covers the rig, setpoints, diluent switches and bailout end to end.

The screen, top to bottom

A plan is one scrolling screen in three parts. Knowing which part you are in makes the rest of this guide easier to follow.

  1. The inputs. Four sections, in this order: Dive Profile (your levels), CCR (the rebreather rig, on every plan whether or not you use one), Gases (OC / Bailout Gases on a rebreather plan), and the Settings tile. Each level, gas and rig block is its own outlined tile: tap it to edit. Sections start folded to a one-line summary, so the plan’s results are close: Dive Profile reads “2 levels · 45 m max · 30 min”, CCR reads Disabled or the diluent, the setpoints and any dilout, Gases lists its mixes. A problem inside a folded section stays on its summary line in amber or red (”▲ ρ 5.3”), so folding never hides it. Tap the summary to open the section as one box, and its title or arrow to fold it again. Each plan remembers what you opened.
  2. The scope block. Three rows that say which version of the plan you are looking at: the scenario tabs, the CCR view chips (rebreather plans only), and the Modifiers line. This block sticks to the top of the screen once you scroll past it and releases when you scroll back up, so a stop table thirty rows down never loses the plan it belongs to. On a tablet, where the results are the long column, it pins above them for the same reason.
  3. The results. The difference pills, the dive profile graph, the stop table, the Gas Consumption card, and Plan Next Dive.

A floating stats pill sits at the bottom of the screen the whole time, where the tab bar would be, with runtime, time to surface, CNS, OTU, gas density and, when there is a problem or a note, the plan’s status. On a tablet in landscape the inputs and the results become two columns that scroll independently.

The planner recalculates as you edit. There is no calculate button.

Plan a dive

Open the planner and start a plan

From the Plan tab, open Deco Planner. You land on the plan list, newest plan first. Tap Create New Plan at the top of the list, choose Fresh Dive (your defaults, no prior tissue loading) or Repetitive Dive (continues from a previous plan after a surface interval you set), and press the button at the bottom of the sheet, which reads Create Fresh Dive or Create Repetitive Dive. With no saved plans yet, Create New Plan skips the choice and opens a fresh one.

Name the plan

Rename in the header menu sets the plan name, up to 50 characters. Give it something you will recognise later, for example “Wreck 45 m Tx21/35”.

Build the dive profile

A new plan starts as a single level, 30 m (100 ft) for 15 minutes on your default gas (air in one AL80 until you change it). Tap the level to change its depth, time and gas, or tap Add Level for a multi-level profile. See The dive profile.

Add your gases

In the Gases section, add at least one bottom gas plus any deco gases. Each gas carries a mix, a cylinder, a fill pressure, and an optional reserve of its own. See Gases in the Deco Planner.

Check the settings, or accept your defaults

Tap the Settings tile for gradient factors, ascent and descent rates, the last stop and step size, PPO₂ caps, oxygen breaks and warning thresholds. Most divers leave these on their saved defaults. See Deco Planner settings.

Read the results

The stop table, the runtime, the time to surface, the gas required per cylinder and the warnings all update as you type. See Reading a deco plan.

The dive profile

The dive is described as one or more levels, each a depth and a time. The Dive Profile section lists them in the order you dive them, one tile per level.

For a square dive, use a single level. For a multi-level profile, add a level per segment, deepest part first. Add Level seeds the new row 6 m (20 ft) shallower than the last one, for 10 minutes, on Auto gas. Long-press a row and drag to reorder: the order of the levels is the order of the dive, so reordering changes the schedule.

To delete a level, open it, scroll to the end of the sheet and tap Delete, which asks first. A plan’s only level has no Delete, because a plan needs a level.

A level with zero minutes is a travel stop: the dive passes through it without staying. On the way up, it is how you mark a gas switch. 100 m (330 ft) on 12/60 followed by 65 m (215 ft) for 0 minutes on 20/25 climbs to 65 m on the 12/60, switches to the 20/25 there, and starts the ascent on it. Versions 2.10.0 to 2.11.3 skipped that switch: the ascent stayed on the 12/60, or the plan showed “Current gas not in list” when the 12/60 was excluded from deco.

Reading a level row

Each tile shows the level’s depth and time large, the gas on the right, and a line of readings underneath. Only a reading over its limit is coloured: amber with ▲ for a warning, red with ■ for critical.

What you seeWhat it means
45 m · 20 minThe level’s depth and time. A swap icon and Travel stop instead of a time means a travel stop (zero minutes)
A gas pill, like 21/35The gas that level breathes after Auto has resolved it, written as O₂/He (21/35, 50/0, 100/0) and coloured by its mix. Auto above it means Auto picked it; no caption means you pinned that cylinder
Loop over SP 1.3A rebreather level on the loop, with its setpoint. A level riding a dilout reads SP 1.3 · 18/30
An OC badgeOn a rebreather plan, this level is breathed open circuit rather than on the loop
A ▲ or ■ after the timeThis level has an issue none of its readings shows (a hypoxic gas, a missing cylinder). Open the level to read it under Issues at this level
PPO₂ 1.16The oxygen partial pressure at that depth on that gas, always in bar. It turns amber or red past that gas’s limit
END 32mThe equivalent narcotic depth, shown only when it is shallower than the level, so it never appears on air or any helium-free mix
ρ 5.1The gas density at that depth in g/L, coloured against your warning and critical thresholds
NDL 12 minThe no-stop time left at that level. Reads NDL 12 min · last stop required when the plan still has to pause on the way up. See below

Between two rows that change gas, a small indicator names the switch and, when you have set a gas switch time, what it costs: 21/0 → 50/0 (+2 min).

The NDL tag on a level

A level row can carry an NDL tag with the minutes of no-stop time left there. It is computed at your plan’s GF High, the same conservatism the engine applies on the bottom, so it reads shorter than an agency table. Five minutes or less turns the tag amber.

A dive can show no-stop time on a level and a stop in the table below it at the same time, and both are right. A profile that touches the GF Low line is routed through the last stop and held there by the minimum stop rule, even when its ceiling is zero the whole way up. That stop is required, but it is not decompression, so the level keeps its no-stop figure and the tag adds last stop required to say which kind of stop the table is showing. When a ceiling really does hold you somewhere, the tag carries no such note.

It is deliberately absent more often than it is there. A level that already owes a stop has no no-stop time left, so nothing is shown rather than a 0. A level shallow enough to sit there indefinitely shows nothing either, because “no practical limit” is not a figure to plan against. On a bailout view the engine reports nothing at all and the tag stays away. The tag always describes the base plan, not the contingency tab you happen to be on; contingency tabs carry their own NDL difference pill instead.

The level sheet

Tap a level to open its sheet. Depth and Time are steppers, one above the other; type into either or use − and +. Under them a strip shows the PPO₂, END and gas density of the gas this level will breathe, worked out as you change the numbers. A figure over its limit turns amber or red, and the words under it say which limit (“over 1.4”).

Delete, at the end of the sheet, asks before it removes the level. Long press a level in the list and drag to reorder it.

Find max time to reserve, under Time, works out the longest time at this level’s depth with every cylinder still at its reserve, and sets Time to it. It runs the plan with the level as it stands in the sheet, on the gas you picked, using your reserve rule. The line under the button names the cylinder that reaches its reserve first. It is a gas figure only, with no allowance for gas sharing, cold, current or workload, and it is not offered on a CCR plan, where the scrubber is the limit. Change the depth or gas and the line clears; tap again for a new answer. For a time limited by TTS, or to search a contingency tab, use the Bottom time finder on the results.

When the gas you picked is too rich for the depth, the depth stepper turns red and says why: “21/35 reaches PPO₂ 1.47 bar here. Its MOD is 56 m.” The plan still runs; the level and the plan’s warnings flag it until you change the depth or the gas.

The sheet saves when you close it, by swiping it down, tapping outside it, or going back. Delete at the end of the sheet removes the level. Travel stop turns the level into a zero-minute gas switch, and Issues at this level lists every warning the level carries, with the numbers.

Which gas a level breathes

Open a level and the Gas row offers Auto first, then CCR on a rebreather plan, then one chip per cylinder in your gas list.

Auto is the default on every new level and is what most plans want. It takes the highest-PPO₂ gas whose maximum operating depth covers that level, and the sheet says which one it picked and why, in a line under the chips. Auto also looks ahead on the initial descent: while each level is deeper than the one before, it only picks a gas you can keep breathing to the bottom of that descent, so a shallow first level (a bubble check, say) never grabs a deco gas on the way down. Once the profile steps back up, every later level, including a shallow interval between two deep excursions, keeps the richest safe gas. If no gas in your list covers both depths, as on hypoxic trimix dives, Auto falls back to the richest gas that is safe at the level itself.

The chip Auto picked is outlined in blue. A cylinder whose MOD does not reach the level’s depth says so under its name (MOD 21 m); you can still pick it, and the level then shows the problem.

Pick a cylinder chip instead and you pin that level to that gas. The tile then loses its Auto caption, and the plan keeps your choice even when Auto would have chosen differently.

CCR puts the level on the loop. The Setpoint stepper is editable only when you pick CCR yourself: when Auto put you on the loop, the same slot shows the rig’s value as a read-only line, 1.3 bar · set by Auto. A Diluent row appears below when the rig has more than one diluent option, so you can send one level onto a dilout. See CCR diving.

When the gas switch happens

Levels change gas, and where the change happens matters: it decides which cylinder pays for the leg between them, what oxygen pressure you breathe on the way, and what the plan can safely assume. There are three cases.

Going deeper. You switch before you descend, at the depth you are already at, and go down on the new gas. The deeper level’s gas is the leaner one, so it is safe where you are standing, and there is no later moment at which you could safely take it up.

Coming shallower. You ascend on the gas you are already breathing and switch when you arrive. The shallower level’s gas is the richer one, and it is only safe once you are shallow. Leaving 75 m on a 35/38 would start that ascent at an oxygen partial pressure (PPO₂) of 2.98 bar, roughly twice any limit, which is why the planner will not put you on it until you get where you are going.

Staying at the same depth. You switch in place.

Your Switch Time is recorded where the switch happens, on the gas you are leaving: at the departure depth before a descent, at the arrival depth after an ascent. The gas it costs is charged to the cylinder you are switching TO, the same convention the ascent’s own gas switches use.

Stops in front of a level you planned

Put a level shallower than your current ceiling and the planner will not fly you up to it. It runs that ascent the way it runs any other: every stop your tissues owe between the two levels, the gas switches those stops call for, and then the last hop down to your level. Your level’s own gas takes over when you arrive, and the dive carries on from there.

That means you can put a point anywhere in your profile, including inside the decompression. A stop at 21 m to hand off a stage, a photo stop on the way up, a second descent after a shallow leg: the planner keeps every obligation honoured around whatever you add.

A worked example, published in full as scenario W1 of the MultiDeco comparison. A diver planned 75 m on 17/60, then added a 21 m level for 8 minutes on their 35/38. The planner ascends on the 17/60, switches to the 35/38 at 30 m where that mix first becomes safe, and arrives at 21 m with nothing skipped: 48.3% CNS and 661 litres out of the stage bottle.

Before this it modelled the whole 54 m ascent on the 35/38 from the moment it left 75 m. That charged about 900 extra litres to the stage, and because the oxygen exposure was counted over the whole leg (2.98 bar of PPO₂ at the bottom of it, 2.0 bar at its midpoint), the plan printed a CNS above 100% and a critical warning for a dive that does not have one.

Travel stops

A level with a time of zero is a travel stop: a depth you pass through to change gas, not a depth you stay at. The Travel stop toggle in the level sheet sets the time to zero, and typing 0 into the time field turns the toggle on. Turning it off sets the time to one minute.

Your gas switch time still applies at a travel stop, so the switch itself costs whatever you set under Gas Switch. On an exported slate a travel stop prints as one switch row rather than as a depth and time pair.

Descent

The planner descends at the Descent rate in your settings. The default is 20 m/min (66 ft/min). Descent time counts toward the runtime and toward gas consumption.

The rate applies to every descending leg, not only the one from the surface to your first level. If a later level is deeper than the one before it, the planner descends to it at the same rate. The descent is modelled as a continuous ramp rather than a jump, so the time you spend on the way down loads your tissues exactly as a real descent would.

That makes the rate a real planning tool, not just a runtime detail. To model a deliberately slow descent, set a low rate: at 2 m/min the planner takes 15 minutes to reach 30 m (100 ft), and that quarter hour on-gasses your tissues the way the real descent would. The row prints the time to reach 30 m (100 ft) under the value, so you can see the effect without doing the arithmetic.

There is no per-level descent rate. One rate governs the whole dive.

One behaviour to understand: the Include travel in level time toggle, in the Behaviour section of the settings. When it is on, the travel time to reach a level is counted inside that level’s entered time rather than added on top. If you enter a level time shorter than the travel required to reach it, the planner warns you and the at-depth stay becomes zero minutes.

Saved plans

The plan list opens when you tap Deco Planner, newest plan at the top, and it groups repetitive-dive chains together. A chain keeps its dives in order (dive 1 above dive 2) and sits where its most recent dive would, so adding the next dive to a chain brings the whole chain to the top. Each card carries the plan name, a line under it with the circuit and gradient factors (“OC · GF 50/80” or “CCR · GF 50/80”), and one line of tags: a status word when the last result had a problem (Caution, Critical or Invalid), Imported when the plan came in from a shared link, on a rebreather the first loop level’s setpoint, then the plan’s gases as O₂/He marks, each mix once (the diluent first on a rebreather). When they do not all fit on the line, the last mark reads “+3” for the ones left out.

The card then shows MAX DEPTH, BOTTOM TIME and RUNTIME in one strip, and a footer line with the time to surface, the CNS percentage (amber or red past your CNS warning or 100 %) and the level count. Bottom time is the sum of the times you planned for the levels, so with Include travel in level time on it includes the travel. A repetitive chain is drawn as one group in dive order, with a blue bar down its left edge and the surface interval between the dives.

The ⋯ on a card offers Duplicate, Rename and Delete. Deleting a plan other dives chain from warns you that it breaks the chain.

Create New Plan is the main button at the top of the list. Under it, Import opens the share sheet so you can scan a QR code or paste a link, and Edit Defaults opens the Deco Planner defaults.

Repetitive dives

A repetitive dive starts with the tissue loading the previous dive left you, so it owes more decompression than the same profile dived fresh.

Create one either from Create New Plan → Repetitive Dive, where Continue from shows the plan you are continuing from (your newest, until you tap it to pick another), or from Plan Next Dive at the bottom of a plan you already have open, which chains from that plan and asks nothing else. Both then want the Surface Interval between the two dives. It opens at 60 minutes, steps in 15-minute increments, and 15 minutes is the shortest it accepts. If the plan you chose has been deleted in the meantime, the planner says so and creates nothing, rather than start a fresh dive with no tissue loading.

The chain is visible in the plan list, and Chain to Previous Dive in the header menu attaches an existing plan to one. A surface interval you get wrong changes the schedule, so check it before you dive the second plan.

Variants

A variant is a second version of the same plan kept side by side: the same dive at GF 40/70, say, or with a different deco gas. Create Variant in the header menu, or the + at the end of the variant tabs, asks for a label and adds a tab at the top of the editor.

Each variant tab carries an eye toggle that draws that variant’s profile on the graph as a dashed ghost line, so you can see two ascents at once (a legend under the graph names each dashed line and its run time), and a ⋮ with Rename, Set as Default (promotes the variant to be the plan) and Delete. The base tab is labelled Default until you rename it. On a variant, the results open with Against Default pills (RT, TTS, CNS) that say how the variant differs from it.

Promoting swaps the two tabs whole, names included. A plan called “One bailout” with a variant called “GF 40 70” becomes a plan called GF 40 70 with a variant called One bailout, so the entry in your saved plans list is renamed too. That is what “promotes the variant to be the plan” means: the variant is now the plan, under its own name, and what used to be the plan is kept beside it as a variant. Rename either tab afterwards if you would rather the plan kept its old name. Sharing or exporting while a variant is selected names the variant on the card.

The header menu

The ⋯ in the plan header holds everything that acts on the whole plan.

ItemWhat it does
ShareOpens the share sheet: QR code, share link, copy link. See Share links
ExportOpens the slate export: PDF, PNG or plain text. See Printing and exporting
RenameRenames the plan, up to 50 characters
Create VariantAdds a variant of this plan
TutorialOpens the in-app Deco Planner tutorial
Find bottom timeOpens the bottom time finder. Hidden on a rebreather plan, on a bailout view, and on a plan with no gases, because it cannot answer there
Chain to Previous DiveContinues this plan from an earlier dive’s tissue loading
Delete PlanDeletes the plan and all its variants, after a confirmation

On a tablet, a share icon sits beside the ⋯ and opens the same share sheet.

The whole menu is hidden on a read-only plan.

Share and export a plan

Two different jobs, two different routes.

  • Share link and QR code hand over a live plan. The link carries every input, so your buddy opens the dive you planned and their own copy of the engine recomputes it. See Share links and QR codes.
  • Slate export produces a fixed card for the water: an A6 PDF, a PNG, or plain text, with two schedules side by side on A5 if you tick Compare. See Printing and exporting a slate.

Behaviour and limits

  • The plan is a model. It assumes the gases, depths, rates, and settings you entered are exactly what you dive. Reality (cold, work, current, an off blend) makes you on-gas faster than the model predicts.
  • The planner does not know your real cylinder fills or your actual breathing rate on the day. Verify gas analysis and reserves before every dive.
  • Repetitive plans carry forward tissue loading from the previous dive across a surface interval, and an imported plan can carry tissue state too. A wrong surface interval changes the schedule.
  • Dive Kit does not model a scrubber, thermal stress, or work of breathing beyond the gas density reading.
  • Always dive within your training and certification, and follow the most conservative of your computer, your team’s plan, and your judgement.

Parts of this guide were drafted with AI assistance and may contain mistakes. It's educational, not a substitute for training. Always dive within your certification and verify with your instruments.