Contents

Tools

Mix Result

Work out the final O₂%, He%, and pressure you get, either by adding gas to one cylinder (Fill) or by joining two cylinders with a transfill whip (Decant).

Last updated October 30, 2026

Free web calculator: Nitrox and Trimix Top-Up Calculator →

On this page

What it is

The Mix Result tool answers a forward question: “what do I end up with?” It works two ways, switched by the Fill / Decant toggle at the top. The difference is where the pressure gauge is.

  • Fill: you add measured gas to one cylinder from a bank or supply, reading that cylinder’s own gauge. Use it for “add 20 bar of O₂, then 100 bar of air, what do I get?”.
  • Decant: you join two cylinders with a transfill whip and read the single gauge on the whip. Use it for “I poured one cylinder into another, what’s in each now?”.

The in-app title is “Mix Result”. It lives at the plan/mix-calculator route.

Fill mode

Set the cylinder’s current contents and pressure, list the gases you’re adding, and the tool lists each addition in order and gives you the resulting mix and final pressure.

  1. Set the Current Cylinder: its pressure, O₂% and He%, in one row. Both gas fields always show, so leave He% at 0 for air or nitrox and set it for trimix or heliox. Or tap Quick Fill to load a saved gas preset (its mix, with its working pressure as the current pressure), or pick a common cylinder.
  2. Add one or more gases under Add Gas, each with its O₂%, He%, and the pressure To add. The O₂, Air and He buttons in the card header fill in the two gas fields for you; type any other mix. The pressure to add is how far this cylinder’s own gauge climbs, not the final pressure: to top a cylinder from 50 to 150 bar, add 100 bar. The strip under the fields shows this: supply, then your cylinder with its gauge. The form opens set to 100% O₂ at a 5 bar increase, and He% goes back to 0 after each add.
  3. If Add Gas is greyed out, the line under the fields says why: the pressure to add must be above 0, and O₂ and He can’t both be 0%.
  4. Read the result card under the inputs. Its top line is the answer: the gas name and final pressure (“EANx28 at 55 bar”), with the exact O₂% and He% and when to analyse under it. Each added gas follows as a step, for example “Add O₂ to 55 bar”: the pressure the cylinder’s gauge reads after it, and under it the mix it then holds and the pressure that gas added (“Then O₂ 28.2% · +5 bar”). The ✕ on a step removes that one gas; Reset beside the answer clears them all. Before you add a gas, a dashed box says what will appear here.
  5. If you picked the cylinder with Quick Fill and the gauge would read above its working pressure after your last addition, an amber Target above working pressure warning under the answer gives both numbers. It is a warning only; the result is the same.
  6. Optionally tap Environment to set altitude and the fill versus ambient temperature in a sheet. A hot (or cold) fill ends the steps with a shaded note, “Let it cool to 187 bar”, with the hot pressure and both temperatures.

Decant mode

Decant covers the other scenario: two cylinders joined by a transfill whip. You open both and let them equalize. When the gas stops flowing, both cylinders, and the whip gauge, sit at one settled pressure: the average of the two starting pressures weighted by cylinder size. A whip equalizes pressure but not composition, so only the lower-pressure cylinder’s mix changes (it takes on the other cylinder’s gas), while the higher-pressure one keeps its mix and just drops to the settled pressure. There is no source or target to pick: the tool works out which way gas flows from the two pressures.

  1. Enter Cylinder A and Cylinder B: each one’s size (water volume), current pressure, and mix. Quick Fill loads a saved cylinder.
  2. Read the result under the cylinders: the pressure both settle at (“Settles at 123 bar”) and which way the gas flows.
  3. Two shaded cards, one per cylinder, give what happened to it (“A · received”, “B · donated”), its final pressure and mix, the exact O₂% (and He%), and what it was before.

The strip at the top shows which way gas flows on the whip, from the fuller cylinder to the emptier one. If both cylinders start at the same pressure, no gas flows: an amber “Already equal” card says so in place of the result. If a cylinder size is cleared, a dashed box asks you to enter both sizes.

To plan a partial transfer (top a cylinder up toward a target mix, stopping before they fully equalize), use the Blend Planner’s Decant mode instead. That is a planning operation, not something Mix Result estimates.

How Mix Result differs from the Blend Planner

These tools run the same physics in opposite directions.

  • Mix Result (this tool) works forwards: you know what you did (a fill or a decant) and it tells you the mix you get.
  • Blend Planner works backwards: you give it the mix you want and it tells you the steps to reach it. The Blend Planner has its own Decant mode too: give it a target mix for the cylinder you’re topping off and it tells you the pressure to fill the receiver to, plus what is reachable from your donor.

Reach for Mix Result when you’re starting from what’s in the cylinder. Reach for the Blend Planner when you’re starting from the mix you need.

Inputs and outputs

InputMeaningNotes
Current O₂% / He%What’s already in the cylinderBoth fields always show; set to 0 for nitrox, enter a value for trimix or heliox
Current pressureStarting cylinder pressureGauge pressure, in your unit (bar or psi)
Added gas O₂% / He%Composition of each gas you addOne row per addition
Added pressureHow much pressure each addition contributesSequential, in order
AltitudeSets atmospheric pressureOptional; altitude changes the surface pressure the mixing uses
Fill / ambient temperatureThe temperature during filling and where the gas settlesOptional; drives the cooldown/warm-up step
OutputMeaning
AnswerAt the top of the result card: the resulting gas name (rounded to the whole percent, as EANx32 or TMX 28/35), its pressure after settling, and the exact O₂% and He% to one decimal
StepsEach gas you added, in order, with the gauge reading after it, the mix the cylinder then holds and the pressure the gas added
Let it cool / warm to noteThe shaded last step when fill and ambient temperatures differ, with the hot pressure and both temperatures
Target above working pressureAn amber warning when Quick Fill picked the cylinder and the fill goes past its working pressure; the result is unchanged
Decant resultThe settled pressure, then one card per cylinder (received or donated, pressure, mix, what it was)

How the math works

Mixing works on absolute pressures (gauge plus atmospheric). At low pressure it reduces to Dalton’s Law of partial pressures:

FO₂_final = (P_abs_current × FO₂_current + dP × FO₂_added) / P_abs_final

Helium mixes the same way. Dive Kit adds a real-gas correction on top (see below). Oxygen and helium fractions don’t change with temperature, but pressure does, so the temperature correction uses Gay-Lussac’s Law:

P_settled = P_hot × (T_ambient_K / T_fill_K)

That’s why a hot fill shows a “cool down to” step and a cold fill shows a “warm up to” step. All of this runs in decimal arithmetic (Decimal.js), so long chains of steps do not pick up floating-point rounding.

In Decant mode, the settled pressure two joined cylinders reach is the volume-weighted average on absolute pressures:

P_settled = (P_A × V_A + P_B × V_B) / (V_A + V_B)

Both cylinders end at that settled pressure. The lower-pressure cylinder’s new mix is the same partial-pressure blend as a Fill top-up, using the higher cylinder’s gas; the higher cylinder keeps its mix. Decant uses altitude only, no temperature settling, and the settled gauge pressure does not depend on altitude.

Pressure reads in your chosen unit (bar or psi); the calculation is metric internally and converts at the display boundary.

Real gas, not the ideal-gas rule

Fill mode uses a real-gas (compressibility) model, not the ideal gas law that blending courses teach for hand calculation. At fill pressures the gases do not pack quite the way the simple rule assumes, so a result can differ by a fraction of a percent from what a partial-pressure chart predicts. For nitrox the gap is tiny, well inside what your analyzer reads. It is larger and one-directional for helium, where an oxygen analyzer cannot catch the error, so getting the number right up front matters more for trimix. Decant uses the same real-gas model. Either way, the analyser reading is the one you dive.

Behaviour and limits

The result is a calculation, not a measurement. Always analyse the finished cylinder with an oxygen (and helium) analyser before diving, and label it.

Input ranges: pressure goes up to 500 bar (7252 psi), altitude up to 10000 m (32800 ft), and fill and ambient temperatures from -100 to 100 °C (-148 to 212 °F). Above 500 m the Environment sheet notes how much lower the atmospheric pressure is; an ambient temperature above 30 °C or below 5 °C adds a note that the cylinders will lose or gain pressure as they settle.

Decant uses the real-gas model for both the settled pressure and the resulting mix, but assumes an isothermal transfer. In the real world a freshly decanted cylinder is warm, so once it cools it reads a little lower than the settled figure, and a transfill whip holds a small dead volume of gas. A whip is also too slow for the two mixes to blend across it, which is exactly why the lower cylinder ends up with a different mix from the higher one. Analyse both cylinders after the gas settles.

  • Blend Planner is the reverse tool: give it the mix you want and it gives you the fill steps to get there.

Parts of this guide were drafted with AI assistance and may contain mistakes. It's educational, not a substitute for training. Always dive within your certification and verify with your instruments.