Contents

Tools

Best Mix Calculator

Find the richest nitrox or trimix blend for a target depth, or the MOD for a mix you already have, within your chosen PPO₂ limit.

Last updated October 30, 2026

Free web calculator: Best Mix Calculator for Nitrox and Trimix →

On this page

What it is

The Best Mix tool answers two questions that every nitrox and trimix diver asks before a dive. First: for the depth I’m planning, what’s the richest oxygen mix that stays within my PPO₂ limit? Richer is better because more oxygen means less inert gas and less decompression. Second: I have this mix in my cylinder, so how deep can I take it? That deepest point within the limit is the Maximum Operating Depth, or MOD.

Both answers come from the same physics. Oxygen turns toxic once its partial pressure (PPO₂) climbs too high, and partial pressure rises with depth. Pick a PPO₂ ceiling, and the math fixes the relationship between oxygen fraction and depth. Dive Kit does that math with the real surface pressure (1.01325 bar at sea level) and your water type, so its MOD can sit a few tenths of a metre shallower than the 10 m per bar rule of thumb; see Conventions. The screen and the home card both call it Best Mix.

The tool has two modes you switch with the segment at the top: Nitrox and Trimix. Each mode keeps its own values. The screen reads top to bottom: one card of inputs, then a caption line, the standard mix, and three result tiles. The mix to fill is the O₂ (and, in Trimix, He) in the input card: there is no separate answer line.

How to use it (Nitrox)

Pick your PPO₂ limit

The Max PPO₂ row at the bottom of the card sets the limit in bar: 1.2, 1.4 or 1.6. 1.4 is the common working limit. 1.6 is reserved for deco stops and resting. 1.2 is a more conservative working limit for long exposures. Other opens a sheet where you step the limit in 0.05 bar steps or type any value from 0.10 to 10.00 bar, with quick picks for 1.0, 1.1, 1.3 and 1.5 and a preview of what the limit does to your current mix (“EANx34 good to 32 m”). Tap Use to apply it, or Cancel to keep the old limit. The Other chip then shows the value you picked.

Set the depth or the mix

Step or drag Max depth to your planned depth and Oxygen follows with the best mix for that depth. Or step or drag Oxygen and Max depth follows with how deep that mix can go. The value you moved last has a blue outline; the other is marked auto.

Read the result

The Oxygen value is the mix to fill (34 % is EANx34). Under the card, a line with an ⓘ names the standard fill: the richest common nitrox (21, 28, 32, 36, 40 or 50 %) that stays within your limit at that depth, with its MOD, for example “Standard fill: EANx32, good to 33 m”. The three tiles under it check PPO₂, END and density at Max depth.

The two steppers stay linked through your PPO₂ limit, so changing either one keeps the pair consistent. PPO₂ is always shown in bar and is never converted, but depth follows your unit setting (metres or feet), so the tool works the same in imperial.

Nitrox mode starts at EANx28 with a PPO₂ limit of 1.4 bar and an MOD just under 40 m. Oxygen runs from 21% to 100%. Max depth starts at 1 m, and its top end moves with your PPO₂ limit rather than sitting at a fixed number: it is the deepest a 21% mix could be breathed at that limit, since 21% is the leanest nitrox, capped at 60 m. At the default 1.4 bar that works out at 56 m. Raise the limit to 1.5 or 1.6 bar and the cap takes over at 60 m; drop it to 1.2 bar and the range ends at 47 m. At the deepest depth the + button turns dashed, the hint reads “deepest at 1.4 bar”, and a line under the card says “Nitrox ends here at 1.4 bar. Trimix goes deeper.”

The standard fill uses the same 0.03 bar tolerance as every PPO₂ check in the app, so at 40 m on 1.4 bar it names EANx28, good to 39 m: EANx28 reaches 1.404 bar at 40 m, inside the tolerance, while its MOD at exactly 1.4 bar is 39.8 m.

How to use it (Trimix)

Trimix mode adds helium and a narcosis target. Max depth is a stepper with a slider; O₂, He and the equivalent narcotic depth (END) are typed into one row of linked fields, and the Max PPO₂ limit is typed in bar under them (there are no PPO₂ chips in Trimix mode).

The tool links four values in two pairs so you can start from whatever you already know:

  • Depth and O₂ are tied together by your PPO₂ limit. Change one and the other follows.
  • END and He are tied together by the narcosis formula. Set the END you’re comfortable with and the tool computes the helium needed. Type He and it shows the END you’d get.

A value the tool worked out is marked auto and says where it comes from: “from depth”, “from END” or “from He”. The value you entered has a blue outline. N₂ is shown read-only in the Gas Composition header.

The O₂ and He fields are the mix to fill. He shows one decimal (35.8 %); when you order the fill, round helium up, never down, so the cylinder never carries less helium than your END target needs. The help sheets name the mix that way (35.8 % reads TMX 19/36). When the mix contains helium, a line under the card names the nearest standard trimix: the richest of 25/25, 21/35, 18/45, 15/55, 12/60 and 10/70 that stays within your PPO₂ limit (with the 0.03 bar tolerance), is not hypoxic, and keeps the END within your target at that depth. It prefers a mix whose recommended range covers the depth (“Nearest standard: 18/45, 48 to 60 m” at 60 m). When no range covers the depth, it names the richest one that passes, with its MOD (“Nearest standard: 18/45, good to 221 ft” at 200 ft).

Trimix mode extends the limits: O₂ can drop as low as 5% and depth reaches 300 m. The default target END is 30 m. The Max PPO₂ field accepts 0.1 to 10 bar. Helium can run from 0% up to whatever is left after oxygen (100 minus O₂).

Inputs and outputs

FieldMeaningNotes
Max PPO₂Your oxygen partial-pressure ceiling, in barNitrox: chips 1.2 / 1.4 / 1.6 plus Other (0.10 to 10.00 bar). Trimix: a typed field (0.1 to 10 bar)
Max depthPlanned maximum depthNitrox: 1 m to the deepest 21% reaches at your PPO₂ limit, capped at 60 m (56 m at 1.4 bar). Trimix: 1 m to 300 m. Metric or imperial per your settings
Oxygen / O₂Oxygen fraction of the mixNitrox: a stepper with a slider (21% to 100%). Trimix: a typed field (down to 5%)
HeHelium fraction (trimix only)Typed field. Worked out from your END target, or set directly. Range 0% to (100 minus O₂)
ENDEquivalent narcotic depth you’ll accept (trimix only)Typed field. Drives the helium. Default 30 m
Caption”at 30 m · EN 13319 · 15 °C”: the depth the figures are for, and the water type and temperature from Settings › DivingMore figures on the right opens or closes EAD, EADD and NDL
Standard lineThe standard fill (Nitrox) or nearest standard trimix, with its depthQuiet ⓘ line; the hypoxic warning and the nitrox depth limit join it when they apply
PPO₂ (oxygen)Oxygen pressure of the mix at Max depth✓ within 1.4, ▲ deco only (above 1.43 bar), ■ too high (above 1.63 bar)
END (narcosis)How deep the mix feels for narcosis at Max depth✓ within, ▲ over the END warning in your deco defaults (30 m by default)
Density (breathing effort)Gas density at Max depth, in g/L✓ easy, ▲ elevated (above 5.2), ■ too high (above 6.2)
EAD, EADDEquivalent air depth and equivalent air density depth (under More figures)EAD is replaced by Min depth for a hypoxic mix
NDLNo-stop time at Max depth, at your default GF high (under More figures)“0 min” in amber means a stop is already required on arrival

A tile turns amber with ▲ when a figure crosses its limit and red with ■ when it is well past it. More figures stays open or closed the way you left it, also after a restart. Tap any tile to open what it means, with its value for this mix. The END sheet has a Treat O₂ as narcotic row that opens Settings › Diving.

Rounding

The recommended oxygen fraction is always rounded down (floored), never up. Rounding down keeps PPO₂ below your limit rather than nudging it over. So a depth that works out to 17.5% O₂ is reported as 17%, giving you a small safety margin instead of a fractional percentage you can’t fill anyway.

Narcosis and the O₂ setting

In trimix mode the helium recommendation depends on whether you count oxygen as narcotic. There’s a Treat O₂ as narcotic toggle for this in Settings → Diving. If oxygen is treated as narcotic, everything except helium contributes to narcosis, so the tool recommends more helium. If only nitrogen is narcotic, it recommends less. Both conventions are in common use; the tool simply follows your choice. A footnote under the results says whether END was calculated with O₂ as narcotic or non-narcotic, with a Change in Diving settings link.

Warnings

  • PPO₂ limit above 1.6 bar. When the Max PPO₂ you set is above 1.6 bar (with the 0.03 bar tolerance), the limit turns red with the reason: a PPO₂ that high risks oxygen toxicity, which can cause convulsions and loss of consciousness underwater. This applies to the Other sheet and the Nitrox chips, and to the Trimix field. The tool still lets you use the value.
  • Hypoxic mix (Trimix only). When the recommended O₂ drops below 18%, the result is hypoxic and not breathable at the surface. This only happens in Trimix mode, since Nitrox mode floors O₂ at 21%. Min depth (in red) replaces EAD under More figures, and a red line under the card gives the minimum depth where the mix becomes breathable (where PPO₂ reaches 0.16 bar) and reminds you to use a travel gas to reach that depth.
  • HPNS (Trimix only). Deep helium dives raise the risk of High Pressure Nervous Syndrome (HPNS). From 80 m with at least 10% helium, an “HPNS possible this deep” link appears beside Max depth. It is informational, not a red hazard; it opens a note that reminds you to descend slowly.
  • Gas density. The Density tile turns amber or red as it climbs, since dense gas is hard to breathe and drives up CO₂. Amber starts above 5.2 g/L and red above 6.2 g/L. Tap the tile and its sheet names the helium that would bring the mix under 5.2 g/L at that depth; Best Mix never adds it for you. These thresholds come from published research (Anthony and Mitchell, 2016) and are adjustable in your deco defaults. The density reading itself is computed at the water temperature you set in Settings → Diving (15 °C by default), because colder gas is denser. The two thresholds do not move with that setting, so picking warmer water reports a slightly thinner gas and the colour changes a little deeper. Gas Specs explains the full formula.

Behaviour and limits

While you type into O₂%, the tool may briefly read a partial number: typing 18 passes through 1 first. When the O₂ sits outside the mode’s own range (5 to 100% in Trimix, 21 to 100% in Nitrox), the depth, He and every figure show a dash, and the line under the card reads “Finish typing O₂ (5 to 100 %)”. They come back as soon as the O₂ is in range again. The value you typed is kept as it is.

The field you are typing into stays above the keyboard: the screen scrolls it into view.

On a tablet held in landscape the screen splits into two columns: the inputs on the left, and on the right the caption, the standard line and the result tiles. Each column scrolls on its own. On a phone, or on a tablet held upright, the tool stays one column.

This tool plans a mix. It does not replace analysing the gas in your actual cylinder with an oxygen (and helium) analyser before you dive.

  • Gas Specs analyses a mix you already have at any depth.
  • Deco Planner builds the full decompression schedule for the gases you’ve chosen.

Parts of this guide were drafted with AI assistance and may contain mistakes. It's educational, not a substitute for training. Always dive within your certification and verify with your instruments.