Tools
Blend Planner
Plan exactly how to fill a target nitrox or trimix from what is already in the cylinder, by partial pressure or continuous flow.
Last updated October 31, 2026
Free web calculator: Gas Blending Calculator →
On this page
What it is
The Blend Planner tells you how to physically fill a cylinder to a target mix. You give it what is in the cylinder now, the mix and pressure you want, and the gas you have to blend from. It hands back the steps in order: how much to bleed off, what to add from which bank, and to what pressure. In the app this screen is titled Blend Planner.
It is the reverse of the Mix Result tool. Mix Result tells you what mix you get when you top up a cylinder; Blend Planner works backwards from the mix you want and tells you how to get there.
The planner runs in three modes you switch between at the top: Partial (partial-pressure blending, the default), Continuous (continuous-flow blending for a mixing panel), and Decant (top a cylinder off from another cylinder through a transfill whip, with no bank or compressor).
Partial-pressure blending
This is the standard method: you add each gas in turn and watch the pressure climb, because at a fixed temperature each gas adds pressure in proportion to how much of it you put in.
On first open the screen comes pre-loaded with an example: a Trimix 18/45 target from 150 bar of leftover EANx32 in an 11 L cylinder, so you see a real multi-step plan straight away. Edit the Current and Target values to match your own fill.
Set up the cylinder
The Now → Target card holds the cylinder as it is and the fill you want, one row per value: O₂, He and Pressure, with the Now field on the left and the Target field on the right. Under them goes the size: in metric the water volume in litres, with the free gas it holds beside it; in imperial the capacity in ft³ and its rated working pressure, the way an AL80 means 80 ft³ at 3000 psi. Quick Fill in the card header pulls a saved cylinder profile and sets the size and the target mix and pressure in one tap. Leave He at 0 for a nitrox fill. Raising O₂ or He lowers the other if the two would pass 100%.
Pick or save the cylinder (optional)
The bar under the card holds your saved cylinders by the names you gave them: Current first, then your saved cylinders, then + Save. Tap a chip to load it; tap the selected one again (it shows •••) to rename or delete it. A saved cylinder keeps its size, contents and target only: banks and environment are shared across all of them.
Follow the fill plan
The fill plan sits in one card. Its top line is the answer, the target mix and pressure (“TMX 18/45 at 200 bar”), with the mix the plan actually reaches under it (“Fill plan · Achieved 17.9/45.1”). The steps follow in order, the pressure to stop at as the big number on the right. Under each add step you see the mix the cylinder holds once that gas is in, and for a Limited bank its own pressure before and after (“bank 120 → 99”). When the planner finds more than one way to make the fill, Option 1, Option 2 and so on sit inside the card to switch between them, ranked by how close they land first and fewest steps second. With only one way, there is no switch.
Set up your banks and environment
Shop setup at the bottom of the page lists your banks with their limits, and your environment, because you set them once for your fill station. Tap either to open its sheet. In the Banks sheet, tap a bank to edit it, or Add Bank for a new one. In the editor you set O₂% and He%, then Capacity: Unlimited (a shop supply that never runs out) or Limited (a bottle with a size and current pressure, so the plan respects how much gas it holds). Air, O₂ and He are there by default as Unlimited banks; Delete is in the editor’s header. Environment sets altitude, ambient temperature and fill temperature. Sea-level defaults are fine for most fills.
What the steps mean
| Step | What you do |
|---|---|
| Bleed to | Drain the cylinder down to the stated pressure before adding gas. Needed when the current mix is too rich, or to make room for the right blend |
| Add (gas) to | Fill from that bank up to the stated pressure. The line under it shows the O₂% and He% once it is in |
| Let it cool to / Let it warm to | You filled warmer (or cooler) than the room: the pressure settles to the stated figure as the gas reaches ambient temperature |
Under the plan, Total gas used lists what each bank gave, measured from the cylinder’s starting pressure: the free gas it took, and the pressure it added to your cylinder (“+98 bar”) or, for a Limited bank, the bank’s own drop (“bank 120 → 99”).
A plan that works shows no status badge: only problems take space. When a step takes the cylinder above 40% O₂, the line under that step turns amber and gives the O₂ it reaches: that part of the fill needs an O₂-clean cylinder, valve and whip, and a slow fill. A plan that bleeds the whole cylinder down gets an amber card above the steps.
When no plan works, one red card takes the place of the steps and says why in two lines (for example “Needs a helium bank”, or “Target can’t be reached” with the O₂ range your banks can make), with an Add Bank button and the Shop setup card right under it. When the banks get part of the way, the card says the plan stops short and the partial plan follows. A value the planner can’t use (a cylinder volume of 0) turns that field red with the reason, and the results show a dashed No plan. A cylinder already holding the target reads Already at target.
Target above working pressure
When the planner knows the cylinder’s working pressure (you picked it with Quick Fill, or entered the imperial capacity and its rating) and the target pressure is above it, an amber Target above working pressure warning appears under the card with both numbers, for example “232 bar is more than this cylinder’s 207 bar working pressure.” Filling to exactly the rating raises nothing. The warning never changes or blocks the plan. Typing a volume by hand in metric clears the known rating, so the warning stays quiet until you pick a cylinder again.
Continuous blending
Continuous mode is for shops with a mixing panel that blends gas as it flows into the cylinder, rather than adding it in pressure steps. Switch to the Continuous tab.
The panel feeds are fixed: Air, O₂, and He are metered into the air intake, so the only shop setting is the altitude. You set the cylinder’s Now and Target values in the same card as Partial mode (Continuous keeps its own saved cylinders). The results are one card of steps, headed by the blend the panel must produce in the fill line (for example “EANx32 blend”) and “Set the flows, then fill to 200 bar”. When the cylinder already holds gas, a line under it reminds you this is the gas in the line, not the cylinder’s final mix.
| Step | What you do |
|---|---|
| Bleed to | Only when the current mix is in the way: drain to this pressure first (rounded down to 5 bar, or 100 psi) |
| Set the flows | Set the Air, O₂ and He share of the intake flow on the rotameters, for example “Air 86.1% · O₂ 13.9% of the intake” |
| Analyzer reads | The O₂ to expect on the in-line analyzer. A trimix fill has two: Analyzer 1 after the first port, Analyzer 2 the final blend |
| Fill to | Run the compressor up to the target pressure |
For trimix, the Gas Injection Order switch (He-first / O₂-first) under the steps changes Analyzer 1’s reading; its (?) shows both plumbings. Gas used lists the free gas drawn from each feed. At the very end a tip repeats the rule for the intake: keep it at or under 40% O₂ unless the compressor is rated for oxygen service. When the blend goes above 40% O₂, an amber warning above the steps says the compressor and kit must be O₂-compatible and O₂-clean.
When no continuous blend can make the target from what is in the cylinder, a red card says why and a line under it offers Switch to Partial: a partial-pressure fill from your banks may still make the mix.
Decant
Decant mode plans a top-off from one cylinder into another, with no bank or compressor: you join them with a transfill whip and let gas flow from the fuller one into the one you are topping off. Switch to the Decant tab.
This is deliberately limited, and the tool is built to show you the limits before you commit. With one finite donor and only one control (when you close the valve), the cylinder you are topping off can reach only the mixes on a straight line from its current mix toward the donor’s mix, and only up to the pressure at which the two settle.
Enter both cylinders
Set Donor (Decant From) and then Receiver (Topping Off), the order the gas flows: each one’s size, current pressure, and mix. Quick Fill loads a saved cylinder. The donor needs to be at higher pressure than the receiver.
Read what is reachable
Under the target, the tool shows the envelope: the range of mixes you can reach and the pressure they settle at, for example “EANx32 up to EANx43, at 123 bar”. That tells you upfront whether your goal is even possible from this donor.
Set your target mix
Enter the O₂% and He% you want in the receiver. Two cards answer it side by side. Fill to is the pressure to stop the receiver at, with the mix it reaches (“Receiver reaches EANx40. Close the donor to read it.”). Donor left is what stays in the donor, with its unchanged mix.
When a target cannot be reached, the tool does not just refuse. If it is richer than this donor can deliver, or for trimix off the blend line, an amber card says why and the two cards still show the closest mix you can reach and its fill pressure, so you can take it or change the target. If the donor is not at higher pressure, or the target is the wrong way from the donor, a red card replaces both, since there is nothing to stop at.
Inputs and outputs
Pressure and volume follow your unit settings (bar or psi, litres or cubic feet). Cylinder sizes are entered in your sizing language: water volume in metric, capacity at working pressure in imperial, with a hint under the fields showing the computed counterpart. Oxygen and helium are entered as percentages.
| Input | Meaning |
|---|---|
| Current state | The cylinder’s size, pressure, O₂%, and He% right now |
| Target state | The O₂%, He%, and pressure you want to end with |
| Banks (partial only) | The gas sources you can blend from, Unlimited or Limited. Continuous mode has no banks: its feeds are fixed (Air, O₂, He) |
| Environment | Altitude, ambient temperature, and fill temperature (its own sheet, from the Environment tile; Continuous and Decant use altitude only) |
| Output | Meaning |
|---|---|
| Fill plan / steps | Headed by the target (partial) or the blend (continuous): the ordered bleed, add-bank and settle steps (partial), or bleed, set the flows, analyzer readings and fill to (continuous) |
| Achieved mix | The mix the plan actually reaches, under the target |
| Fill to / Donor left | The pressure to stop the receiver at and what stays in the donor (decant) |
| Target above working pressure | An amber warning when a known working pressure is below the target; the plan is unchanged |
Real gas, not the ideal-gas rule
The Blend Planner plans with a real-gas (compressibility) model, not the ideal gas law that blending courses teach for hand calculation. At fill pressures the gases do not pack quite the way the simple partial-pressure rule assumes, so a planned fill pressure can differ by a bar or two from what an old blending chart says. For nitrox that gap is tiny, well within what your analyzer reads. It is larger for helium, where an oxygen analyzer cannot catch the error, so a trimix plan is where the real-gas math matters most.
The planner solves each fill against this model and rounds the pressures it chooses to whole bars, so every step is something you can read and set on a gauge. The one number it never rounds is the pressure you entered. 800 psi is 55.2 bar, not 55, and the plan starts from what is really in the cylinder. A bleed step only shows up when there is at least a bar (about 15 psi) to dump, since nothing smaller is an instruction you could follow. Working in psi, the intermediate targets are whole-bar values converted for you, so they land on numbers like 984 psi rather than round hundreds.
This is a target, not a guarantee: a fast fill heats the cylinder and the pressure drops as it cools, by more than the real-gas correction itself. The Decant mode keeps the simpler ideal equalization model on purpose, since a decant’s real-gas shift is tiny next to that cooling.
Behaviour and limits
- The plan assumes your inputs are exact. Analyse what is already in the cylinder before you trust a plan that builds on it; never assume a cylinder’s contents.
- Limited banks are respected, so the planner will not propose drawing more gas than a portable bottle holds. Unlimited banks assume an endless shop supply.
- A target has to be a blend of your banks and the gas already in the cylinder, taken as a whole, not one gas at a time. With oxygen, helium and air banks, 3/45 is out of reach: air is your only nitrogen, and it brings 21 parts oxygen for every 79 of nitrogen, so at 45% helium the leanest you can make is about 12% oxygen. The planner says so and gives the oxygen range your gases can reach at that helium. It also counts only the gas actually in the cylinder: EANx50 at 110 bar topped up with air reaches at most about 37% at 200 bar.
- Always analyse the finished mix with a calibrated analyser before you breathe it or log it. The planner is a guide to the fill, not a verification of it.
Related
- Mix Result is the reverse: it tells you the mix you get from a top-up.
- Deco Planner is where you plan the dive these gases are for.
Parts of this guide were drafted with AI assistance and may contain mistakes. It's educational, not a substitute for training. Always dive within your certification and verify with your instruments.